Model number: LMK-16R-DV-B
RF Relay Module with Softswitch — 16 A(adaptable box not included)
The RF relay module with Softswitch is a radio frequency (RF) device that uses Lutron patented Softswitch technology to control up to 16 A of general-purpose loads based on input from RA2 Select, RadioRA 2, and HomeWorks systems.
- Lutron patented Softswitch technology prevents arcing of relay contacts, extending product lifetime.
- Various operating voltages available—refer to Models chart below for details on voltage requirements.
- Capable of switching 16 A of general-purpose loads.
- Utilizes Lutron Clear Connect RF technology—refer to Models chart below for frequency band data and Lutron system compatibility.
- Mounts to an electrical junction box through a 1/2 in (21 mm trade-size) knockout opening.
- Complies with requirements for use in a compartment handling environmental air (plenum) per NEC® 2011 300.22(C)(3) (LMJ- model only).
Specification
Power | 120/277 V~ 50/60 Hz 16 A 0.5 HP at 120 V~ 1.5 HP at 277 V~ (LMJ- model) 220–240 V~ 50/60 Hz 16 A motor: 6 A (LMK-, LMM-, LMN-, LMQ- models) |
Typical Power Consumption | < 1.0 W Typical power test conditions: all loads off, top LED on |
Regulatory Approvals | UL®, UL 2043 Plenum Rated, FCC Approved. Complies with the limits for a Class B device, pursuant to Part 15 of the FCC rules: CSA, IC, NOM, ANATEL (LMJ- model) CE, TRA, CITC (LMK- model) WPC (LMN- model) |
Environment | Ambient operating temperature: 32 °F to 131 °F (0 °C to 55 °C) Ambient operating humidity: 0% to 90% humidity, non-condensing. Indoor use only. |
Communications | Operates using Clear Connect RF technology for reliable wireless communication; refer to Models chart on page 1 for band frequency details. RF range is 30 ft (9 m) from repeaters. Contact Lutron for applications using foil-backed or metallic ceiling tiles. |
Load | Maximum load: 16 A general purpose. No minimum load requirements. Load types include, but are not limited to: Incandescent, MLV, ELV, Resistive, Inductive, Magnetic fluorescent, and Electronic fluorescent. |
Surge Protection | Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits. |
Mounting | Mounts to an electrical junction box through a 1/2 in (21 mm trade-size) knockout opening. |
Warranty | www.lutron.com/TechnicalDocumentLibrary/Warranty.pdf www.lutron.com/TechnicalDocumentLibrary/Intl_Warranty.pdf |