Model number: RMKS-250NE
The Vive in-line dimmers can control lighting both locally and remotely when paired with Pico wireless controls or Radio Powr Savr occupancy / vacancy sensors. This provides a system that is convenient and easy to install. Vive in-line dimmers use Lutron robust Clear Connect RF technology which provides reliable, wireless communication with other Vive devices. Each load control can be controlled individually using a Pico wireless control. A Vive hub enables a simple setup process using a standard web browser on any Wi-Fi enabled phone, tablet, or computer. It also enables control and monitoring of all Vive devices. The Vive hub can be added at any time. System reprogramming will be required.
Features
• The reverse-phase dimmer is trailing-edge capable of up to 250 W of incandescent / halogen / ELV loads and up to 1 A / 150 W of LED.• Receives wireless inputs from up to 10 occupancy sensors, 10 Pico wireless controls and 1 daylight sensor.
• To maximize energy savings and provide hands-free operation, load controls can be turned on / off automatically via Radio Powr Savr occupancy / vacancy sensors.
• Small size allows for simple retrofit installation.
• Easily scalable into a smart system by adding a Vive hub.
• Configurable high-end and low-end trim when paired with a Pico wireless control or Vive hub.
Specifications
Regulatory Approvals• CE (RMKS model only)
• IDMA (RMMS model only)
• WPC (RMNS models only)
• Compliant to IEC 60669-2-5
Power and Ratings
• 220–240 V~ 50 / 60 Hz
Typical Power Consumption
• < 0.5 W; Test conditions: Load and LED are off
Environment
• Operating temperatures 0 °C to 40 °C (32 °F to 104 °F )
• Relative humidity: 0% to 90% non-condensing
• For indoor use only
Communications
• Vive in-line dimmers communicate with the system through Radio Frequency (RF)
• Dimmer must be located within 18 m (60 ft) line-ofsight or 9 m (30 ft) through walls of a Pico wireless control, Radio Powr Savr sensor, or Vive hub
• System devices operate at frequencies of 868 MHz, 868 MHz Limited, 865 MHz, or 434 MHz Limited ESD Protection
• Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2
Surge Protection
• Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41- 1991 Recommended Practice for Surge Voltages in Low-Voltage AC Power Circuits
Power Failure
• Power failure memory: Should power be interrupted, the control will return to its previously set level prior to the interruption when power is restored
Mounting
• Allow adequate space to ensure convective cooling of load control. Remove any insulation,heat generating equipment, or obstructions within 120 mm (4.75 in) of the load control
• For optimal RF performance, no metal or other electrically conductive material should be present within 120 mm (4.75 in) around the top and sides of the load control. The load control is not suitable for installation in places where it is fully enclosed in metal (e.g., metal enclosures, electrical cabinets) or within metal ceilings
Metal Ceiling Tile Mounting
• Metal ceiling tile grids must have a greater than 3 mm (0.12 in) gap of non-metallic material which extends the entire length of the tile on at least one edge. This is often achieved by foam spacers that are used to prevent tile-to-tile rattling
• Metal ceiling tile grids which are continuous (with no gap) or those that are interlocked, must have a total surface area that is less than 81 m2 (266 ft2) for each section. The overall space can be larger as long as there are non-metallic sections bordering or intersecting the metal sections